Flow Sensors
CS2 Correlation Pipe Sensor
Part No. CS2-V3Large measurement range for big pipes
Ultrasonic sensors for flow measurement with very high accuracy in slight to heavily polluted media. For installation in pipes up to 5000 mm diameter
- Very high accuracy by means of ultrasonic cross correlation method
- Interference-free connection over long distances through digital signal transmission
- Cable extensions over several 100 metres with standard cables possible without any problems
- Absolutely stable zero point and drift-free
- Measurement in slightly to heavily contaminated media
- Suitable for media with high solids loads
- Easy installation without additional constructions thanks to optimised mounting accessories
- Installation under process conditions possible
- Particularly suitable for pipe sections starting at 1000 mm diameter
The pipe sensors are designed for mounting from the outside into the pipelines using nozzles. In combination with transmitters such as NivuFlow 750 or NivuFlow 7550 and an additional external level measurement, they form a complete flow measurement system for part filled applications. They can also be used for permanently full pipes or Channels. The additional height measurement can be omitted here.
Typical applications for CS2 pipe sensor
- Channel networks: billing measurement places, flow measurement in large pipe sections
- Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
- Pump stations: pumped quantities
- Industrial wastewater networks
- and many more
| General | |
|---|---|
| Measurement principle | Correlation with digital pattern recognition (Flow Velocity)
|
| Measurement frequency | 1 MHz |
| Protection | IP 68 |
| Ex-Approval |
|
| Operating temperature |
|
| Storage temperature | −30 °C to +70 °C |
| Operating pressure | max. 4 bar (for combi sensors with pressure measuring cell max.1 bar) |
| Cable lengths |
|
| Cable types | LiYC11Y 2 x 1.5 + 1 x 2 x 0.34 |
| Outside cable diameter | 8.4 mm ±0.25 mm |
| Sensor types | Flow velocity sensor with v-measurement by cross-correla-tion and temperature measurement to compensate for the influence of the latter on the speed of sound |
| Construction | Pipe sensor for installation in pipes with sensor screw joint and retaining element |
| Medium-contacting materials | Polyurethane, stainless steel 1.4571, PPO GF30, PEEK, PA6 |
| Measurement range | −350 cm/s to +600 cm/s |
| Max. Measuring span | Δ 700 cm/s |
| Quantity of scan layers recorded and computed | Max. 32 |
| Zero point drift | absolutely stable zero point |
| Error limits (per scan layer) |
|
Specifications subject to change.
EC type examination certificate sensor type POA, OCL and CS2
EC type examination certificate sensor type POA incl. supplement

![[Translate to English:] Installation Durchflussmessung - Vergleich bei DN 800 [Translate to English:] Durchflussmessung - Installationsvergleich](/fileadmin/_processed_/1/c/csm_Durchflussmessung-Rohrsensor_b7a18d158d.jpg)
![[Translate to English:] Durchflussmessung Ultraschall Kreuzkorrelation [Translate to English:] Durchflussmessung Ultraschall Kreuzkorrelation](/fileadmin/_processed_/e/8/csm_Cross-Correlation-Priniciple-Pipe_8b0e2b98b8.png)