CS2 Correlation Pipe Sensor

Part No. CS2-V3

Large measurement range for big pipes

Ultrasonic sensors for flow measurement with very high accuracy in slight to heavily polluted media. For installation in pipes up to 5000 mm diameter

  • Very high accuracy by means of ultrasonic cross correlation method
  • Interference-free connection over long distances through digital signal transmission
  • Cable extensions over several 100 metres with standard cables possible without any problems
  • Absolutely stable zero point and drift-free
  • Measurement in slightly to heavily contaminated media
  • Suitable for media with high solids loads
  • Easy installation without additional constructions thanks to optimised mounting accessories
  • Installation under process conditions possible
  • Particularly suitable for pipe sections starting at 1000 mm diameter

 The pipe sensors are designed for mounting from the outside into the pipelines using nozzles. In combination with transmitters such as NivuFlow 750 or NivuFlow 7550 and an additional external level measurement, they form a complete flow measurement system for part filled applications. They can also be used for permanently full pipes or Channels. The additional height measurement can be omitted here.

 

Typical applications for CS2 pipe sensor

  • Channel networks: billing measurement places, flow measurement in large pipe sections
  • Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
  • Pump stations: pumped quantities
  • Industrial wastewater networks
  • and many more

 

 

Technical Data
General
Measurement principle

Correlation with digital pattern recognition (Flow Velocity)

 

Measurement frequency

1 MHz

Protection

IP 68

Ex-Approval
  • II 2 G Ex ib IIB T4 Gb (ATEX)
  • Ex ib IIB T4 Gb (IECEX)
Operating temperature
  • −20 °C to +50 °C
  • −20 °C to +40 °C if using the sensors in Ex Zone 1
Storage temperature

−30 °C to +70 °C

Operating pressure

max. 4 bar (for combi sensors with pressure measuring cell max.1 bar)

Cable lengths
  • For sensors without plugs (sensor connection type "K" and "L") extendable to max. 250 m cable length. 
  • For sensors pressure measurement cell (level measurement Type VxD0/VxU1), a pressure compensation element is required for cable lengths over 30 m, which can also be used to connect the extension. 
Cable types

LiYC11Y 2 x 1.5 + 1 x 2 x 0.34

Outside cable diameter

8.4 mm ±0.25 mm

Sensor types

Flow velocity sensor with v-measurement by cross-correla-tion and temperature measurement to compensate for the influence of the latter on the speed of sound

Construction

Pipe sensor for installation in pipes with sensor screw joint and retaining element

Medium-contacting materials

Polyurethane, stainless steel 1.4571, PPO GF30, PEEK, PA6

Measurement range

−350 cm/s to +600 cm/s

Max. Measuring span

Δ 700 cm/s

Quantity of scan layers recorded and computed

Max. 32 

Zero point drift

absolutely stable zero point

Error limits (per scan layer)
  • < 1 % of measurement value (v > 1 m/s)
  • < 0,5 % of measurement value +5 mm/s (v < 1 m/s)

Specifications subject to change.

Downloads

Technical Instructions | Correlation Sensors and external Electronic Box (Rev. 12)

Mounting Instruction | Correlation and Doppler Sensors (Rev. 08)

EC type examination certificate sensor type POA, OCL and CS2

EC type examination certificate sensor type POA incl. supplement

IECEx Certificate of Conformity "Sensors type POA, OCL and CS2"

EU Declaration of Conformity | Ultrasonic Active Sensors POA / OCL / CS2

EU Declaration of Conformity | “Ex” Ultrasonic active sensors POA / OCL / CS2

 

Tender Specification CS2 Sensor

System Products
Accessories

Haven't found the appropriate product?

You haven’t found the right product? Then use our application configurator – it will get you to the right product step by step.

Individual Offer / Questionnaire

Also for your individual measurement spot we support you gladly. Please fill in our questionnaire.

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

Hello!
We are happy to answer any questions you may have about water and digitalization. We look forward to your call or email.