Contactless Flow Measurement on Fish Ladder

Flowing Waters - Special Constructions


Application

  • Concrete intake channel
  • 3.0 x 2.0 m (w x h)
  • Part filled
  • Gravel bed

Definition of tasks

  • Flow measurement to ensure a minimum water volume required for the fish ladder
  • No sensors can be installed on the channel bottom
  • Contactless measurement if possible on inaccessible point (risk of vandalism)
  • Medium accuracy requirements

Solution

  • A contactless surface radar system Type OFR was installed in the fish ladder approach under     a bridge.
  • The System measures the speed of surface waves resulting from the roughchannel bottom (gravel bed). The current flow rate is calulated from this velocity and the current flow level     which is measured contactlessly as well.
  • The flow rate is passed on as mA signal to a PLC on site which controls the position of a slide valve upstream of the measurement point

Advantages

  • Contactless measurement system
  • "Invisible" sensors
  • Low installation and commissioning efforts

Used products


Haven't found the appropriate product?

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

Hello
We are glad to have you here! For any question regarding water or digitisation we are happy to answer you call or your email message.
Team NIVUS
Im Täle 2
75031 Eppingen