Application

  • Pipe with 0.25 m diameter, made of cast iron
  • Full filled
  • Overhead tank featuring one single pipeline and flow in both directions

Definition of tasks

  • Comparison between water volumes consumed within the supply network during daytime and the water volumes refilled during nighttime to detect pipeline breaks or leakage
  • Measurement an a single pipeline featuring bidirectional flow
  • Sensors shall be installed in permanently full iron cast pressure pipelines (no shut-off or draining devices available)
Zu- und Ablaufmessung in einem Hochbehälter
Installationsprinzip
Zu- und Ablaufmessung in einem Hochbehälter

Solution

  • A transmitter type Type NivuSonic has been selected to solve the task.
  • One pair of wetted sensors has been used. These sensors have been screwed into 2 pressure-proof tensioning clamps under operating conditions using a drilling device.

Advantages

  • Easy, straightforward and quick upgrading without the need to drain the pipe
  • High accuracy and reliability

Used products

Haven't found the appropriate Application?

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Applications & Solutions

Applications & Solutions Our Applications and Solutions catalogue offers a brief overview to the most interesting application examples in a single pdf-document.

We will keep you informed.

Find out all you need to know about NIVUS - product news, special promotions, practical examples and much more