Robust measurement system, consisting of transmitter and level probe, for data transmission to the server-based Internet portal "D2W" (Device to Web) via GPRS.
The water level data logger measuring and data recording system is for detection of analog readings from connected 2-wire sensors such as pressure probes. The measurement system operates independent from mains power. Sensor and radio transmission system are powered by high-performance Lithium batteries featuring a very long lifetime (approx. 10 years typical). Detected readings are saved on flash memory and will be transmitted to the server-based Device to Web (D2W) Internet portal via GPRS using the built-in quad band modem.
This Internet portal allows to adjust the settings for communication and data processing as well as the operational settings of the level data collector unit. One of the main benefits of the water level logging system is the option to connect generally all 2-wire sensors by using the integrated terminal clamps. Users hence may select the appropriate sensor for the respective application and, by connecting with the level data connector, obtain a complete measurement system.
Common | |
---|---|
Power supply | Lithium battery 3.6 Volt / 13 Ah for sensor supply and wireless transmission |
Typical lifetime | With hourly storage cycle and pressure probe transmission once per day: approx. 10 years |
Enclosure | material: stainless steel / plastic weight: ca. 1800 g (without level probe) dimensions: 406 mm / ø 48:3 mm; suitable for 2" level pipes protection: IP 68 |
Operating temperature | -20 °C to +60 °C |
Storage temperature | -30 °C to +85 °C |
Max. humidity | 80 %, non-condensing |
Display | red LED (status indicator) for indication of operating conditions and error messages |
Operation | Magnet switch to activate the measurement system |
Inputs | 4 - 20 mA for external 2-wire sensors (pressure probe / compact echo sounder) |
Outputs | Power supply 15 – 17.3 Volt DC, max. 66 mA for 2-wire sensors (pressure probe) |
Storage cycle | 1 to 60 minutes |
Data memory | Internal flash memory up to 70 days with 60 min. recording cycle |
Specifications subject to change.