Level Meter

NivuMaster Transmitter

Part No. NM5; NM6; NMA; NMB; NM9

For level measurement using ultrasonic sensors

For the supply of connected ultrasonic P-Series sensors, processing of signal data and indication of computed readings. Ideal or measurement and control in level and volume applications

  • Measurement of level, distance, volume, difference and flow
  • Alarm output in case of flooded sensor possible
  • Pump control saves energy and costs thanks to intelligent pump management
  • High measurement reliability through intelligent agitator avoidance
  • Connection of maintenance-free, Ex-protected ultrasonic sensors  
  • Up to 6 relays and galvanically isolated mA outputs
  • Easy echo analysis and setting of parameters using free PC software
  • Integrated emergency power switchover
  • Easy operation in dialog mode using back-lit graphic display

The NivuMaster series transmitters supply connected P-Series sensors, process measurement values and indicate readings. NivuMaster transmitters are ideally suitable for simple control tasks in level measurement applications. Flow measurements in open channel using a Venturi flume or Q/h-relations, on any kind of weir or discharge sills are possible without any problems.

NivuMaster is available with wall mount enclosure, as 19"-plugin or with panel mount enclosure.

The few parameters required for measuring can be entered easily on site in dialog mode thanks to the back-lit display and the integrated keypad.
Parameters can be evaluated using the free software “PC Software Suite” and the serial interface of the transmitter.

 

Type overview

NivuMaster L2 (NMX)

Compact standard model with 2 relays for level and volume measurement.

NivuMaster 3 Relays (NM5)

For measurement of level, volume and quantity, for pump control and for extended control tasks.

NivuMaster 5 Relais (NM6)

Extended NivuMaster 3 Relays model including additional control options.

NivuMaster LD-5:2 (NMB)

Model for connection of 2 sensors; particularly for comparative measurements on screening plants. For measurement and output of difference and level.

NivuMaster LF-5:2 (NMA)

Particularly for use in stormwater treatment plants. For independent measurement and output of liquid level and discharge volume using one single sensor.

NivuMaster Plus (NM9)

Model specialised for pump management. For comfortable control of up to 5 pumps and error message output.

 

Typical NivuMaster Applications

  • Wastewater: stormwater overflow tanks and storage sewers, clarifiers, pump stations, screening plants, flow measurements, volume measurements in vessels, container monitoring, irrigation facilities
  • Drinking water: tank level measurements, water treatment, seawater desalination facilities, level measurements
  • Flood protection: stormwater retention tanks, level measurements with remote data transmission, surface waters
  • Power generation: cooling water circuits, hydropower plants
Common
Power supply115 V AC +5 % / -10 %; 50/60 Hz 230 V AC +5 % / 10 %; 50/60 Hz direct current 18 – 36 V DC
Power consumption max. 10 W (6 W typical)
Enclosure material:Polycarbonate, low flammability (UL91)
ProtectionWall mount enclosure: IP 65 Panel mount: IP 65 (front), IP 20 (rear) 19“: IP 20
Operating temperature-20 °C to +60 °C
Storage temperature-30 °C to +60 °C
Max. humidity80 % non-condensing
Displaygraphic LCD display
Operationlocal operation with key panel
Menu languagesEnglish, French, German
Echo processingintelligent agitator avoidance
PC Programmingvia RS232
Ex-ApprovalATEX, Zone 0 / 1
Communication (optional)Modbus RTU Profibus DP

Specifications subject to change.

NivuMaster L2
Part-No.NMX-
DescriptionCompact standard model with 2 relays for level and volume measurement.
Enclosure Wall mount
Inputs1 x sensor input
Outputs2 x relay outputs 1 x mA output

Specifications subject to change.

NivuMaster 3 Relais
Part-No.NM5-
DescriptionFor measurement of level, volume and quantity, for pump control and for extended control tasks.
Enclosure Wall mount Panel mount 19" plug-in unit
Inputs1 x sensor input
Outputs3 x relay outputs 1 x mA output

Specifications subject to change.

NivuMaster 5 Relais
Part-No.NM6-
DescriptionExtended NivuMaster 3 Relays model including additional control options.
Enclosure Wall mount Panel mount 19" plug-in unit
Inputs1 x sensor input 1 x 4-20 mA input (optional)
Outputs5 x relay outputs 1 x mA output

Specifications subject to change.

NivuMaster LD-5:2
Part-No.NMB-
DescriptionModel for connection of 2 sensors; particularly for comparative measurements on screening plants. For measurement and output of difference and level. .
Enclosure Wall mount Panel mount 19" plug-in unit
Inputs2 x sensor inputs
Outputs5 x relay outputs 1 x mA output

Specifications subject to change.

NivuMaster LF-5:2
Part-No.NMA-
DescriptionParticularly for use in stormwater treatment plants. For independent measurement and output of liquid level and discharge volume using one single sensor.
Enclosure Wall mount Panel mount 19" plug-in unit
Inputs1 x sensor input
Outputs5 x relay outputs 2 x mA outputs

Specifications subject to change.

NivuMaster Plus
Part-No.NM9-
DescriptionModel specialised for pump management. For comfortable control of up to 5 pumps and error message output.
Enclosure Panel mount
Inputs1 x sensor input 1 x 4-20 mA input (optional) 7 x digital inputs
Outputs6 x relay outputs 1 x mA output

Specifications subject to change.

Brochure NivuMaster

Brochures / Data Sheets English

NivuMaster – the multifunctional universal device

Overview NivuMaster

Brochures / Data Sheets English

Type Overview NivuMaster Transmitter

Data Sheet NivuMaster Plus (NM9)

Brochures / Data Sheets English

Level device with intelligent pump management

Data Sheet NivuMaster LF-5:2 (NMA)

Brochures / Data Sheets English

Level device for monitoring storm water retention tanks

Data Sheet NivuMaster L2 (NMX)

Brochures / Data Sheets English

Transmitter for non-contact level measurement

Instruction Manual NivuMaster (NM5+NM6)

Instruction Manuals / Technical Information English

Instruction manual for measurement transmitter NivuMaster-Series

Instruction Manual NivuMaster L-2 (NMX)

Instruction Manuals / Technical Information English

Instruction manual for NivuMaster L-2 measuring system

Instruction Manual NivuMaster LD 5:2 (NMB)

Instruction Manuals / Technical Information English

Instruction manual for NivuMaster  LD 5:2 measuring system

Instruction Manual NivuMaster LF 5:2 (NMA)

Instruction Manuals / Technical Information English

Instruction manual for NivuMaster LF 5:2 measuring system

 

Tender Specification NivuMaster 3-Relays (NM5)

Texts for Tender Specification English
 

Tender Specification NivuMaster 5-Relays (NM6)

Texts for Tender Specification English

EU Declaration of Conformity Transformer NivuMaster

Certificates German English

Multifunktionaler Messumformer NivuMaster

EU Declaration of Conformity NivuMaster

Certificates German English

Multifunktionaler Messumformer NivuMaster

  • Ultraschallsensoren P-Serie zur Füllstandsmessung von flüssigen Medien

    P-Series Sensors

    P-Series sensors are suitable for continuous level measurement in the water and wastewater sector....
    P-Series sensors are suitable for continuous level measurement in the water and wastewater sector. For connection to NivuMaster-Series evaluation units. Suitable for harsh ambient conditions.
Flow Measurement at Overflow Sill

Flow Measurement

Detection of overflow volume, overflow time and duration according to German DWA...
Detection of overflow volume, overflow time and duration according to German DWA directives.
Flow Measurement in pump well

Flow Measurement Pumps

Well diameter 1.8 m. Depth of well 6.5 m. Two wet installed pumps. Pressure...
Well diameter 1.8 m. Depth of well 6.5 m. Two wet installed pumps. Pressure pipe installed in the centre.
Level Measurement in Spiral Pump Control

Spiral Pump Control

Wastewater lifting facility with three spiral conveyors. Delivery head approx....
Wastewater lifting facility with three spiral conveyors. Delivery head approx. 9.00 m.
Overflow Volume on Trough

Collection of Overflow Volume

Detection of overflow volumes on long trough-shaped overflow sill with oncoming...
Detection of overflow volumes on long trough-shaped overflow sill with oncoming flow on each side using combined Poleni calculation.
Discharge Measurement without Space in a closed stormwater overflow tank

Overflow Measurement

Reliable non-contact measuring at lowest distance between ceiling and maximum...
Reliable non-contact measuring at lowest distance between ceiling and maximum water level.
Flow Measurement Dump Seepage Water

Dump Seepage Water

Detection of lowest flow volumes in the dangerous case of mineralsedimentation. ...
Detection of lowest flow volumes in the dangerous case of mineralsedimentation.
Flow Measurement in Venturi Flume

Flow Measurement in Venturi Flume

Detection of wastewater treatment plant discharge using existing Venturi flume. ...
Detection of wastewater treatment plant discharge using existing Venturi flume.
Flow Measurement in Plastic Pipe

Flow Measurement Big Pipe

Cooling water (seawater) with max. flow rate of 60.00³/h from power plant. ...
Cooling water (seawater) with max. flow rate of 60.00³/h from power plant.
  • Modulares Montagezubehör für Messumformer zur einfachen Montage

    Transmitter Accessories

    The mounting accessories allow the quick and easy installation of transmitters. The solid...
    The mounting accessories allow the quick and easy installation of transmitters. The solid high-quality accessories made of stainless steel 1.4301 are suitable for indoor and outdoor installation. Transmitters can be simply installed in close vicinity to measurement places. Weatherproof covers protect the transmitters from influences due to weathering in outdoor areas. All accessories are supplied including the according fastening materials.
  • Überspannungsschutz für Messgeräte und Sensoren

    Overvoltage Protection Unit

    DataPro, SonicPro and EnerPro surge arrestors – highly stressable and particularly adjusted to...
    DataPro, SonicPro and EnerPro surge arrestors – highly stressable and particularly adjusted to sensors and transmitters. Maximum operational safety at small dimensions.
  • Overvoltage protection enclosure

    BSG 12, 32, 42 and BSG 20 Ex - for DataPro, SonicPro, EnerPro and IsoPro surge arrestors
    BSG 12, 32, 42 and BSG 20 Ex - for DataPro, SonicPro, EnerPro and IsoPro surge arrestors
  • PC Software Suite

    PC Software Suite

    Software package for NivuMaster, NivuCompact, i-Series sensors and NivuScope 2. Functions: setting...
    Software package for NivuMaster, NivuCompact, i-Series sensors and NivuScope 2. Functions: setting of parameters, echo profile analysis and documentation of parameters and echo profiles
  • i-Serie intelligente Sensoren zur Füllstandsmessung

    i-Series Sensors

    Ultrasonic sensors with integrated transmitter for measurement of distance, level, empty space or...
    Ultrasonic sensors with integrated transmitter for measurement of distance, level, empty space or volumes. Suitable for harsh ambient conditions.

Haven't found the appropriate product?

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

We will keep you informed.