Water Quality & Analysis

NivuParQ 850

Part No. NP8-5

Continuous measurement of particle concentration (TSS equivalent) with new ultrasonic measurement method using multi-frequency echo

Particle Concentration Measurement

measure. continuously. easily. maintenance-free.

The determination of solids concentrations with the parameter TSS (total suspended solids) is becoming increasingly important due to legal requirements (e.g. European Water Framework Directive, DWA A-102). In order to ensure good water quality, the requirements for rainwater treatment plants and discharges into water bodies are becoming ever more stringent.

The NivuParQ 850 measurement system makes it easy to take continuous particle concentration measurements in rainwater, surface water or hydroelectric applications. The low-maintenance system can be used in part filled and full channels, canals and pipes of various geometries and dimensions. The measurement technology used is based on ultrasonic backscattering/attenuation and uses complex algorithms to determine both the particle concentration and the particle size distribution in the water. In combination with a flow measurement, the total dirt load can be determined.

Your Benefits

  • Continuous and drift-free measurement of particle concentration (TSS equivalent) using new ultrasonic measurement method with multi-frequency echo
  • Measurement in the flow cross-section
  • Determination of five particle size classes
  • Very low operating costs, as no time-consuming sampling with laboratory analysis is required
  • Easy installation and quick and easy operation
  • Low-maintenance and reliable measurement system
  • Low investment costs for measurement place setup
  • Additional measurement parameters through integrated temperature and level measurement
  • IoT-ready with global 4G connectivity for maximum availability and digital services

Possible Applications

  • Determining the effectiveness of rainwater treatment plants
  • Measuring precipitation-related dirt load in rainwater discharge
  • Verification of retention filters and solids filters
  • Measuring at the intake of hydroelectric power plants
  • Checking dirt loads from direct dischargers into water bodies
  • Quality-dependent control of rainwater and wastewater
  • Measurement of suspended solids transport in surface waters
Technical Data
General
Measurement range

50…6000 mg/l (10…6000 mg/l at low noise values)

Estimated particle size classes

< 63 µm / 63…100 µm / 100…200 µm / 200…400 µm / > 400 µm

Measurement frequency

1, 2, 3, 4, 6, 7 and 9 MHz

Measurement principle

multi-frequency echo

Measurement condition

Mass density

1100…2650 g/l

Channel shapes

All

Channel dimensions

Min. DN 250

Minimum filling level

≈ 7 cm

Medium type

Rainwater and mixed water, surface water

Sensor

Medium-contacting materials
  • Polyurethane / stainless steel 1.4571 / PPO GF30 / PEEK without and with pressure measurement cell;
  • Hastelloy® with pressure measurement cell
Cable lengths

10 / 15 / 20 / 30 / 40 / 50 / 60 / 70 / 80 / 90 / 100 m

Operating pressure
  • Max. 4 bar without pressure measurement cell
  • max. 1 bar with pressure measurement cell
Operating temperature
  • -20 °C…+50 °C / Ex version
  • -20 °C…+60 °C / Non-Ex version
Ex-Approval
  • II 2G Ex ib IIB T4 Gb / Ex ib IIB T4 Gb
  • ATEX: TÜV 20 ATEX 268840 X
  • IECEx: TUN 20.0009X
Protection

IP68

Temperature Measurement

Measurement uncertainty

±0,5 K

Measurement range

-20 °C…+60 °C

Level measurement - pressure

Measurement uncertainty

< 0.5 % of final value

Zero point drift

max. 0.75 % of final value (0...50 °C)

Measurement range

0…500 cm

Transmitter

Communication
  • Modbus TCP via networks (LAN/WAN, Internet)
  • Modbus RTU via RS485 or RS232
  • Ethernet TCP/IP
Data memory

1.0 GB internal memory, can be read out via USB stick, frontside

Operation

rotary pushbutton, 2 function buttons, menus in German, English, French and other languages

Display

240 x 320 pixel, 65536 colours

Operating temperature
  • DC: -20°C bis +70°C
  • AC: -20°C to +65°C
  • max. humidity 80%, non-condensing
Power supply

100 - 240 V AC, 47 to 63 Hz or 10 - 35 V DC

Specifications subject to change.

Dimensions

Downloads

Brochure NivuParQ 850

Particle Concentration Measurement in Water Industry

Instruction Manual | NivuParQ 850 (Rev. 02)

Technical Description / Mounting Instruction | Particle Concentration Sensor PKM-Vx (Rev. 03)

Technical Instructions | "NIVUS Modbus TCP/RTU" (Rev. 05)

EU Declaration of Conformity | Particle concentration sensor

EU Declaration of Conformity | "Ex" Particle concentration sensor

EU Declaration of Conformity | Particle concentration measurement transmitter with internal modem for remote data Transmission NivuParQ 8xx

Typ NP8-xG…

EU Declaration of Conformity | Particle concentration measurement transmitter NivuParQ 8xx

Typ NP8-xS…

Accessories

Haven't found the appropriate product?

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

Hello
We are glad to have you here! For any question regarding water or digitisation we are happy to answer you call or your email message.