2093 Results found

Return Sludge Flow Measurement

Return Sludge Flow Measurement Wastewater Treatment Plant - Sludge Treatment Application Pipe with 0.7 m diameter, made of stainless steel Fully filled Point of installation in telescopic pipe Definition of tasks Detection of sludge volumes to monitor and to control even sludge discharge from the se

Hot Sludge Flow Measurement

Hot Sludge Flow Measurement Wastewater Treatment Plant - Sludge Treatment Application Pipe with 0.15 m diameter, made of stainless steel Fully filled Medium contains oil and hot sludge High dry substance contents up to 30 g/l Definition of tasks Continuous measurement of sludge coming from a digesti

Flow Measurement in Venturi Flume

Flow Measurement in Venturi Flume Wastewater Treatment Plant - Discharge Area Application Rectangular channel 0.5 x 0.6 m (w x h), made of concrete Partially filled Upgrading an existing Venturi flume with a measurement system Definition of tasks Detection of wastewater treatment plant discharge usi

Partial Discharge Section Flow Measurement

Partial Discharge Section Flow Measurement Wastewater Treatment Plant - Discharge Area Application Pipe DN 500, made of stainless steel Fully filled Service water tapping and feeding point Definition of tasks For secondary clarification control a partial discharge of the WWTP needs to be measured Re

Separation Layer Measurement in Primary Clarifier

Separation Layer Measurement in Primary Clarifier Wastewater Treatment Plant - Preclarification Application Rectangular basin 30 m x 8.5 m with two outlet funnels Basin depth 2.8 m Funnel depth 5.8 m Definition of tasks Sludge discharge control depending on the sludge level Continuous detection of b

Independent Level Measurement

Independent Level Measurement Independent Level Measurement Application Measuring tube with 150 mm diameter No power supply available on site Definition of tasks Groundwater level measurement at multiple level measurement spots Data logger installed in measuring tube Stable and reliable data transmi

Flow Measurement at Overflow Sil

Flow Measurement at Overflow Sil Wastewater Treatment Plant-Stormwater Treatment Facilities Application Pipe with 1.5m diameter, overflow on the side Partially filled Concrete construction Definition of Task Stormwater overflow measurement in intake area of a WWTP according to EC self-monitoring reg

Open Channel Flow Measurement

Open Channel Flow Measurement Wastewater Treatment Plant - Intake Area Application Rectangular channel made of concrete, width 1m Partially filled Strong fluctuation between daily and nightly inflow Definition of tasks Continuous flow rate measurement in a WWTP intake area Additional external level

Detection of Nighttime Volume

Detection of Nighttime Volume Water Supply - Drinking Water Application Pipe with 0.1 m diameter Fully filled Low water volumes of approx. 3 l/s Definition of tasks Detection of problematic low quantities from a drinking water overhead tank during nighttimes Replaces the EMF not working properly due

Deep Well Level Measurement

Deep Well Level Measurement Water Supply - Groundwater Application Deep drilling 150 m Bore diameter 30 mm Definition of tasks Continuous detection of groundwater level Detection using suspended pressure probe Pressure probe appropriate for small bore diameters of 30 mm Easy installation and removal

Ihr Ansprechpartner