Description
- For high-accurate flow measurement by means of ultrasonic cross correlation method
- Interference-free connection over long distances through digital signal transmission
- Cables can be extended without any problems using standard cables
- Absolutely stable zero point and drift-free
- Measurement in heavily polluted and abrasive media
- Easy installation without additional constructions and perfectly matched mounting accessories
- Installation under process conditions possible
- Suitable for all channel cross sections
- The tailored selection of sensor constructions ensures the best possible solution for each application
CS2 flow velocity sensors are suitable for continuous measurement of slight to heavily polluted media in channels mainly featuring high levels.
The wedge-shaped sensors are designed for installation on either the channel wall or the channel bottom. Combined with transmitter types such as NivuFlow 750 and an external level measurement the result is a complete flow measurement system.
Typical applications for CS2 wedge sensors
- Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
- Industrial wastewater networks
- Large Collectors
- Particularly suitable for large channels featuring levels starting at 500 mm
Technical Data
General | |
---|---|
Measurement principle | Ultrasonic Cross Correlation with digital pattern detection (flow velocity) Ultrasonic transit time (level measurement) Piezo-resistive pressure measurement (level measurement) |
Measurement frequency | 1 MHz |
Sensor types | v-sensor with T-compensation v-sensor with T-compensation and h measurement (water-ultrasound) v-sensor with T-compensation and h measurement (hydrostatic) v-sensor with T-compensation and 2 x h measurement (water-ultrasound + hydrostatic) |
Protection | IP 68 |
Ex-Approval | II 2 G Ex ib IIB T4 Gb (ATEX) Ex ib IIB T4 Gb (IECEX) |
Operating temperature | -20 °C to +50 °C -20 °C to +40 °C if using the sensors in Ex Zone 1 |
Storage temperature | -30 °C to +70 °C |
Operating pressure | max. 4 bar (combi sensor with pressure cell max. 1 bar) |
Cable lengths | 10/15/20/30/50/100 m pre-configured, can be extended upon request; a pressure compensation element is required if cables longer than 30 m are used with sensors featuring an integrated pressure measurement cell. The compensation element can be used also to connect the extension |
Cable types | Combi sensor with pressure measurement: LiYC11Y 2x1.5 + 1 x 2 x 0.34 + PA 1.5/2.5 Sensors without pressure measurement: LiYC11Y 2 x 1.5 + 1 x 2 x 0.34 |
Outside cable diameter | Combi sensor with pressure measurement: 9.75 mm ±0.25 mm Sensors without pressure measurement: 8.4 mm ±0.25 mm |
Sensor connection | Cable end pre-configured for connection to OCM CF Cable end with plug for connection to PCM 4 and PCM Pro Cable end with plug and pressure compensation element (sensors with pressure measurement cell only) for connection to PCM 4 and PCM Pro |
Types of construction | - Wedge sensor for installation on channel bottom or channel wall - Pipe sensor for installation in pipes with sensor screw joint and retaining element |
Medium-contacting materials | Polyurethane, stainless steel 1.4571, PPO GF30, PA6 Optional: sensor resistant to chemicals made of PEEK, mounting plate made of Hastelloy C-276; mounting plate made of titanium; cable with FEP coating |
Flow velocity measurement | |
Measurement range | -100 cm/s to +600 cm/s |
Number of scan layers | max. 16 |
Measurement uncertainty | for 0.05≤|V|≤0.5 m/s: E_v=0.5/|V| [%] for |V|>0,5 m/s: E_v=1 % |
Zero point drift | absolutely stable zero point |
Beam angle | ±5 degrees |
Level measurement water-ultrasonic sensor | |
Measurement range | 0.08 to 500 cm |
Zero point drift | Absolutely stable zero point |
Measurement uncertainty | +/- 2.0 mm or 0.2% of measured range (whichever is greater) |
Level measurement – Pressure | |
Measurement range | 0 to 500 cm |
Zero point drift | max. 0.75 % of final value (0 – 50 °C) |
Measurement uncertainty | standing medium: +/- 0.5 of final value (within a range of 0.05 – 5 m) |
Temperature measurement | |
Measurement range | -20 °C to +60 °C |
Measurement uncertainty | ±0.5 K |
Specifications subject to change.