Flow Sensors

CS2 Correlation Wedge Sensor

Part No. CS2-V3

Large measurement range for high flow levels

Ultrasonic sensors for flow measurement with very high accuracy in slight to heavily polluted media. For installation on channel wall or channel bottom

  • For high-accurate flow measurement by means of ultrasonic cross correlation method
  • Interference-free connection over long distances through digital signal transmission
  • Cable extensions over several 100 metres with standard cables possible without any problems
  • Absolutely stable zero point and drift-free
  • Measurement in slightly to heavily contaminated media
  • Suitable for media with high solids loads
  • Easy installation without additional constructions thanks to optimised mounting accessories
  • Installation under process conditions possible
  • Suitable for all channel cross sections
  • The tailored selection of sensor constructions ensures the best possible solution for each application

CS2 flow velocity sensors are suitable for continuous measurement of slight to heavily polluted media in channels mainly featuring high levels.The wedge sensors are designed for mounting on channel walls, on the channel floor and on the inner walls of large pipes. In combination with transmitters such as NivuFlow 750 or NivuFlow 7550 and with level measurements integrated in the sensor or external level measurements, they form a complete flow measurement system.

 

Typical applications for CS2 wedge sensors

  • Wastewater treatment plants: intake, discharge, activated sludge tank intakes, return sludge, recirculation, surplus sludge, digester discharge and flocculant dosage
  • Industrial wastewater networks
  • Large Collectors
  • Particularly suitable for large channels featuring levels starting at 500 mm
Technical Data
General
Measurement principle
  • Ultrasonic Cross Correlation with digital pattern detection (flow velocity)
  • Ultrasonic transit time (level measurement)
  • Piezo-resistive pressure measurement (level measurement)
Measurement frequency

1 MHz 

Protection

IP 68

Ex-Approval
  • II 2 G Ex ib IIB T4 Gb (ATEX)
  • Ex ib IIB T4 Gb (IECEX)
Operating temperature
  • −20 °C to +50 °C
  • −20 °C to +40 °C if using the sensors in Ex Zone 1
Storage temperature

−30 °C to +70 °C

Operating pressure

max. 4 bar (combi sensor with pressure cell max. 1 bar)

Cable lengths
  • For sensors without plugs (sensor connection type "K" and "L") extendable to max. 250 m cable length. 
  • For sensors pressure measurement cell (level measurement Type VxD0/VxU1), a pressure compensation element is required for cable lengths over 30 m, which can also be used to connect the extension. 
Cable types
  • Combi sensor with pressure measurement: LiYC11Y 2x1.5 + 1 x 2 x 0.34 + PA 1.5/2.5
  • Sensors without pressure measurement: LiYC11Y 2 x 1.5 + 1 x 2 x 0.34
Outside cable diameter
  • Combi sensor with pressure measurement: 9.75 mm ±0.25 mm
  • Sensors without pressure measurement: 8.4 mm ±0.25 mm
Sensor types
  • Flow velocity sensor with v-measurement by cross-correla-tion and temperature measurement to compensate for the influence of the latter on the speed of sound
  • Combi sensor with velocity sensor by cross-correlation, level measurement using water-ultrasound and tempera-ture measurement to compensate for the influence of the latter on the speed of sound
  • Combi sensor with velocity sensor by cross-correlation, level measurement using pressure and temperature meas-urement to compensate for the influence of the latter on the speed of sound
  • Combi sensor with velocity sensor by cross-correlation, level measurement using water-ultrasound and redun-dantly using pressure, incl. temperature measurement to compensate for the influence of the latter on the speed of sound
Construction

Wedge sensor for mounting on the channel floor or the channel wall

Medium-contacting materials

Polyurethane, stainless steel 1.4571, PPO GF30, PEEK, PA6 

Flow velocity measurement

Measurement range

−350 cm/s to +600 cm/s

Max. Measuring span

Δ 700 cm/s

Quantity of scan layers recorded and computed

max. 32

Error limits (per scan layer)
  • < 1 % of measurement value (v > 1 m/s)
  • < 0,5 % of measurement value +5 mm/s (v < 1 m/s)
Minimum filling level

8 cm 

Beam angle

±5 degrees

50° 

Level measurement - water-ultrasonic

Measurement range

0 to 500 cm

Measurement uncertainty

+/− 2 mm 

Level measurement – Pressure

Measurement range

0 to 500 cm

Zero point drift

max. 0.75 % of final value (0 - 50 °C)

Measurement uncertainty

≤ 0.5% of the final value 

Temperature measurement

Measurement range

−20 °C to +50 °C

Measurement uncertainty

±0.5 K

Specifications subject to change.

Downloads

Technical Instructions | Correlation Sensors and external Electronic Box (Rev. 12)

Mounting Instruction | Correlation and Doppler Sensors (Rev. 08)

EC type examination certificate sensor type POA, OCL and CS2

EC type examination certificate sensor type POA incl. supplement

IECEx Certificate of Conformity "Sensors type POA, OCL and CS2"

EU Declaration of Conformity | Ultrasonic Active Sensors POA / OCL / CS2

EU Declaration of Conformity | “Ex” Ultrasonic active sensors POA / OCL / CS2

System Products
Applications
Accessories

Haven't found the appropriate product?

You haven’t found the right product? Then use our application configurator – it will get you to the right product step by step.

Individual Offer / Questionnaire

Also for your individual measurement spot we support you gladly. Please fill in our questionnaire.

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

Hello
We are glad to have you here! For any question regarding water or digitisation we are happy to answer you call or your email message.