Electrode Relay

Overfill Cut-Out Device According to § 19 WHG

Part No. ER-107/B

For level switch

Limit level detection of conductive liquids, a measurement systems consists of a double rod electrode and an ER-107 relay

  • Overfill cut-out device according to § 19 WHG
  • Slimline construction, width only 22.5 mm
  • Adjustable sensitivity
  • Potential-free output as SPDT (2 x)
  • Power supply 230 V AC ±10% 48-62Hz, 24 V DC ±10%  (optional)

Construction

The overfill cut-out device consists of the pickup (conductive double electrode) and the electrode relay type ER-107. It provides a binary switching signal at the out-put. This signal can be sent directly or via a signal amplifier to the report device or to the control section and its control element. The overfill cut-out device's components which have no test certificate have to correspond with the sections 3 and 4 of the device's approval principles (ZG-ÜS).

Function

The electrode relay ER-107 provides a measurement voltage which makes a "working current" flow through the signal wire via the built-in resistor in the pickup. As soon as this working current is interrupted (e.g. cable break) this is detected and displayed by the ER-107 and the source contact switches to alarm status. When the filling level of the container reaches the conductive pickup's rods a measurement current is able to flow through the conductive liquid. This current, which is higher in comparison with the working current, is detected by the ER-107 and the alarm message is generated.

The sensitivity can be adjusted within the response range of the probe using a potentiometer.

The ER-107 functions are based on the closed circuit current principle. The alarm status of the relay corresponds with the dead condition of the device.

Hence, beside monitoring and reporting of wire interruptions and level increase up to the pickup's point of response, the ER-107 also monitors working current failures.

The conductive double rod electrode has a G1½" connection thread as standard.

Common
ER 107/B
Power supply230 V AC ±10 % or 24 V DC ±10 % other voltages on request
Power consumption 1 VA
Enclosure - Weight: approx. 150 g - Protection: terminals IP20, enclosure IP40
Operating temperature-20 °C to +60 °C
Storage temperature-30 °C to +80 °C
BauartzulassungZ-65.13-405, Z-65.40-191
Inputs- Open circuit voltage: <10 V AC - Short circuit current: <5 mA - Switching delay approx.: 0.5 s - Sensitivity range: 1 to 30 kOhm
Outputs- Contacts: 2 potential-free SPDTs (simultaneously operated) - Max. switching voltage: 250 V AC; 150 V DC - Max. switching current: 5 (3) A AC; max. 5 A DC - Switching capacity 1: 250 VA DC; 50 to 180 W DC (depending on switching voltage)
Display2 LED zur Signalisierung von Betrieb, Leitungsfehler und Alarm
Double rod electrode according to §19 WHG
Rod length300 mm
Rod diameter4 mm
Rod materialstainless steel (1.4571)
Enclosure Screw joint and head: PPH (Polypropylene) Coating: Polyamide Connection thread G 1½” Pressure 10 bar
Operating temperature-20 °C to +90 °C

Specifications subject to change.

Data Sheet Overfill cut-out Device acc. § 19 WHG

Brochures / Data Sheets English

Overfill cut-out Device acc. § 19 WHG – electrode relay and conductive probes

  • Abspannklemmen und Abzweigdosen für  Füllstandsdrucksensoren

    Level Pressure Sensor Accessories

    The mounting accessories allow the quick and easy installation of hydrostatic level pressure...
    The mounting accessories allow the quick and easy installation of hydrostatic level pressure sensors. The solid high-quality accessories are made of stainless steel 1.4571 and are suitable for indoor and outdoor installation.
  • Wandmontagewinkel für konduktive Stabsonden R1,5“ und Kompaktecholot 3/6

    Limit Level Accessories

    The mounting accessories allow quick and easy installation of limit level sensors. The solid...
    The mounting accessories allow quick and easy installation of limit level sensors. The solid high-quality accessories made of stainless steel 1.4571 are suitable for installation in outdoor and indoor areas.
  • Elektrodenrelais 104 für Grenzstandmessung und Steuerung

    Electrode Relay ER-104

    For limit level detection in conductive liquids as well as control jobs in connection with...
    For limit level detection in conductive liquids as well as control jobs in connection with conductive rod and suspension electrodes
  • Elektrodenrelais 142-143 für Grenzstandmessung und Steuerung

    ER-142 / 143 Electrode relay

    For limit level detection of conductive liquids as well as control of conductive liquids in Ex...
    For limit level detection of conductive liquids as well as control of conductive liquids in Ex areas, for connection of conductive rod and suspension electrodes

Haven't found the appropriate product?

Product Consultation

You want to have best information about our products? Our experts will gladly develop together with you the best system solution for your application.

Service

You have questions about your NIVUS products in use? Our service hotline will readily support you.

We will keep you informed.

Find out all you need to know about NIVUS - product news, special promotions, practical examples and much more